Abstract:
|
In this research the continuously up-flow pilot scale Moving Bed Biofilm Reactor (MBBR) which was consists of combined cylindrical anoxic/aerobic MBBR in nested form with anoxic/aerobic volume ratio equal to 0.16 under fully nitrification-denitrification process were used to treated 4 m34+-N, TN and TP, respectively, while the average Dissolved Oxygen concentration (DO) in aerobic and anoxic MBBRs were 4.49 and 0.16 mg/L, respectively.
Key words: Ammonium nitrogen, anoxic, attached biomass, autotrophic, biofilm, biological treatment, carrier, conventional activated sludge process, heterotrophic, nitrate, nitrite, nitrogen, phosphorus, sequencing batch moving bed biofilm reactor, suspended biomass
|
Abstract
|
PDF
|
HTML |
|
Cite this Reference:
Husham T. Ibrahim, HEQiang and Wisaam S. Al-Rekabi, . Effect of Gas/Water Ratio on the Performance of Combined Cylindrical Anoxic/Aerobic Moving Bed Biofilm Reactors for Biological Nutrients Removal from Domestic Wastewater by Fully Nitrification-Denitrification Processes. Research Journal of Applied Sciences, Engineering and Technology, (13): 2655-2666.
|
|
|
|
|