Abstract
|
Article Information:
Evaluation of Efficiency in Steam Generator of C3 Power Plant at Cap Des Biches in Dakar
A. Kane, I. Diagne, B. Dieng, A Diouf, M. Dieng, M.L. Sow and G. Sissoko
Corresponding Author: A. Kane
Submitted: February 24, 2012
Accepted: March 30, 2012
Published: July 01, 2012 |
Abstract:
|
The aim of the present study is to determine the efficiency of the power plant boiler steam C3 Cape
deer and to evaluate the impact of it. We chose to calculate the return by the empirical formula of Martin which
is based on two important parameters which are the temperature at the exit of the chimney and the ambient
temperature. The calculation of these efficiencies allowed us to make comparative studies with data from the
manufacturer and we have detected anomalies. On this basis we made a number of recommendations for
improvement of the groups in normal, the application will lead to an optimization of the real exploitation of
groups and a performance improvement. We gave various reasons for poor performance of steam generators
and recommendations that can be used both in production efficiency on compliance with operating instructions.
Solutions have been proposed after diagnosis with particular emphasis on compliance with operating
instructions and maintenance schedule.
Key words: Boiler efficiency, boiler results, facilities, heating value, power generation, power plant, steam generator
|